(1) Explosion at the bottom of the furnace

1. Cause of the accident:

1)
The furnace explosion caused by the closure of the flap of the self-controlled gas furnace;

2)
When the gas is supplied, the bottom of the furnace explodes due to the excessive pressure of the two furnaces;

3)
The bottom of the furnace is not tightly sealed, causing the furnace to explode;

4)
When the gas is supplied, the bell valve of the furnace falls prematurely, resulting in the explosion of the bottom of the furnace;

5)
The interlock fails, the blower or pressurizer trips, resulting in an explosion at the bottom of the furnace;

2. Preventive measures:

1)
When using automatic adjustment, the flow rate should not be too small to prevent gas backflow;

2)
When the gas supply is stopped, it is necessary to unify the command, cooperate closely, and have a clear division of labor;

3)
Regularly check whether the holes and water seals are correct;

4)
Regularly check whether each interlock is correct;